We enjoy state-of-the-art digital instrumentation maintained at the highest standards we can attain. This quality control allows researchers to sort cells at high efficiency and purity under the proper conditions or to run analytical experiments with as many as 21 different fluorochromes simultaneously. We are dedicated to providing the best service and training possible to ensure the best results attainable for our research scientists and physicians. When time permits we are available for scientific collaborations to encourage the career growth of the FCSR staff. Please investigate the pages of this website to address your scheduling needs and questions relating to flow cytometry research, methods and fees. Please feel free to contact me directly with any questions you may have.
It is critically important that the Flow Cytometry Core be acknowledged in publications to demonstrate to the NIH that the funding they support us with is being utilized as intended. Please remember this when submitting publications and use the following text to acknowledge the Flow Cytometry Core:
"Flow Cytometry experiments were performed in the Vanderbilt Flow Cytometry Shared Resource. The Vanderbilt Flow Cytometry Shared Resource is supported by the Vanderbilt Ingram Cancer Center (P30 CA068485) and the Vanderbilt Digestive Disease Research Center (DK058404)"
The VUMC Flow Cytometry Shared Resource and associated entities reserve the right to delete or otherwise destroy data 30 days post creation. The resource user assumes all responsibility for data transfer and subsequent data archiving at the time of data acquisition. Data transfers must occur within the time limitations of their scheduled appointments except for the following situations:
If the resource user is unable to transfer their data within the confines of their reservation, an additional reservation must be made to accommodate the data transfer from the instrument workstation within 30 days of data acquisition. All data transfers initiated via VUMC personnel will be in the raw FCS 3.0 format unless otherwise requested. VUMC archives will be in the encrypted BDFACSDiva or SpectraFlo original file formats for the duration of 30 days to preserve gating information. PDF file transfers are available upon request.
All data transfers must be done via an FCSR approved source. Currently approved sources are:
No other means of data transfer are permissible without the consent from FCSR staff.
In the event that the instrument workstations lose access to the internet, Portable data storage devices such as external drives, flash drives etc. will be used.
Portable data storage devices such as external drives, flash drives etc. must be completely erased immediately prior to their usage. The FCSR has purchased flash drive erasers to accommodate this process. Low capacity flash drives are available to be purchased from the FCSR. The cost of the flash drive will be added on to the reservation as a line item within the iLab reservation. No other means of data transfer are permissible on the following instruments without the consent from FCSR staff: BD Fortessas (3 and 5 laser), BD FACSAriaIIIs (Biobubble, Baker, BSL2+).
The Cytek instruments have workstations that are or will be compliant with the new VUMC policies. Server transfers will be permissible once IT has signed off on our cyber security efforts. Users will have their own login credentials to access our server for data transfer.
Eric Skaar, Scientific Director
Scott Hiebert, Scientific Director
David K Flaherty, Managing Director
Email: david.k.flaherty@vumc.org
Laboratory Phone Number: 615.343.8323
Brittany Matlock, Scientific Coordinator of a Shared Resource Facility
Email: brittany.k.matlock@vumc.org
Laboratory Phone Number: 615.343.8323
Olivia Murfield, Core Research Assistant II
Email: olivia.x.murfield@vumc.org
Laboratory Phone Number: 615.343.8323
Emma McLaughlin, Core Research Assistant I
Email: emma.k.mclaughlin@vumc.org
Laboratory Phone Number: 615.343.8323
Hours | Location |
Monday - Friday 9 am- 5:30 pm |
Medical Building North 1161 21st Ave South T-0101 MCN Nashville, TN 37232 |
► Analytical Cytometer System (6) | |||||||||||||||||||||
|
|||||||||||||||||||||
► Cell Sorters (3) | |||||||||||||||||||||
|
|||||||||||||||||||||
► Core Calendars (1) | |||||||||||||||||||||
|